Promo® 1000
Promo® 1000 is a light-scattering aerosol spectrometer system for particle size analysis and concentration determination that can be equipped with all welas® 1100 and 1200 sensors. These sensors allow reliable measurement in the concentration range from < 1 particle/cm3 - 5 • 105 particles/cm3.
With Promo® 1000, particle sizes above 120 nm can be reliably measured, as the unique high-power xenon high-pressure lamp with very high light intensity and the photomultiplier are directly integrated into the aerosol sensor.
Unique are up to four measuring ranges in only one device:
- 0.12 µm – 3.5 µm (additionally in welas® 1000 and Promo® 1000)
- 0.2 µm – 10 µm
- 0.3 µm – 17 µm
- 0.6 µm – 40 µm
Promo® 1000 is famous for up to 128 size channels per measuring range and a concentration range from < 1 particle/cm3 to 5 • 105 particles/cm3.
Variants
More alternatives
Operation principle
Scattered-light aerosol spectrometer system for particle measurement from 120 nm
A touch display ensures user-friendly operation. Measurements can be started quickly, and all data, such as the current number distribution and the number concentration, as well as 24 further statistical values, can be evaluated and displayed in real-time. All incoming data can be stored with a max. the temporal resolution of 1 s. For data transfer, Promo® can also be integrated into a company network.
Promo®has a standard interface and can be controlled by a process control system or a simple Labview program. The Promo® measurement technology:
Promo® has a new, fast 20 MHz signal processing processor, which analyses the progression of each particle signal.
This makes it possible to recognize coincidental events in light scattering measurement technology at the individual signal and correct them (according to Dr. Umhauer / Prof. Dr. Sachweh). This way, increasing the maximum concentration limit to 5 • 105 particles/cm3 is possible5 particles/cm3.
Furthermore, the new signal detection electronics, which include a new, powerful logarithmic A/D converter, allow particles of 120 nm to be measured with a 50 % counting efficiency.
High classification accuracy, high-resolution capability, and a high counting efficiency are the prerequisites for unambiguous particle measurement.
The best size classification accuracy and the best size resolution are guaranteed by the following special features (see Graph 1):
- White light and 90° light-scattering detection ⇒ Unambiguous calibration curve
- Patented T-aperture ⇒ No border zone error
- New digital individual signal processing ⇒ Coincidence detection and correction of the individual signal making it possible to measure higher concentrations
Graph 1: Resolution capability and classification accuracy (1200 sensor)
The Promo® is characterized by its high counting efficiency starting from 0.12 µm!
Graph 2: Counting efficiency with the welas® 1200 sensor
Extensions/Accessories
The Promo® 1000 sensors:
A powerful light source characterizes the welas®1100 and 1200 aerosol sensorswelas ® 1100 and 1200 aerosol sensors are characterized by a powerful light source, and the photomultiplier are directly integrated into the sensor. This technology offers the best size resolution, classification accuracy, and a low detection limit.
The measurement volume size is crucial for coincidence-free particle size and particle number measurement.
With measurements in coincidence, the diameter is measured too large and the number too small. Theoretically, for a coincidence‐free size, i.e., a maximum of one particle in the measuring volume, at a number concentration of 103particles/cm3, the measurement volume extension must not be higher than 1 mm3.
Benefits
Your special advantages
- Measuring range of 120 nm to 40 µm (4 measuring ranges selectable in one device)
- Up to four measuring ranges in only one device:
- 0.12 µm – 3.5 µm (additionally in welas® 1000 and Promo® 1000)
- 0.2 µm – 10 µm
- 0.3 µm – 17 µm
- 0.6 µm – 40 µm
- Up to 128 size channels per measuring range
- Concentration range from < 1 particle/cm3 to 5 • 105 particles/cm3
- Calibration curves for different refractive indices
- Very high and reproducible counting efficiency rate starting at 0.12 µm
- High temporal resolution down to 10 ms
- PDAnalyze analysis software
- Calibration, cleaning and lamp replacement can all be performed independently by the customer
- External control by RS 232 or Ethernet
- Optional: Software PDControl for operation as welas® digital available
- Simple operation
- Low maintenance
- Reliable function
- Reduces your operating expenses
Applications
Individual solutions for various industries
- Determination of the separation efficiency of car interior filters, engine air filters, room air filters, compressed air filters, vacuum cleaner filters, cleanable filters, electrostatic precipitators, oil separators, cooling lubricant separators, wet scrubbers, cyclones and other separators
- Isothermal and isobaric particle size and quantitative determination, for instance in the automobile, chemical, pharmaceutical and food industries
- Analysis of fast, transient processes
- Inspection of smoke detectors
- Particle formation for cloud formation
- Emission measurements
- Immission measurements
Technical features
In detail
- Measuring principle
- Optical light-scattering
- Measurement range (number C_N)
- < 5 • 105 particles/cm3
- Measurement range (size)
- 0.12 – 3.5 µm, 0.2 – 10 µm, 0.3 – 17 µm,
0.6 – 40 µm - Volume flow
- 5 l/min, 1.6 l/min
- Size channels
- Max. 128 (64/decade)
- Time resolution
- ≤ 1 s
- Interfaces
- USB, Ethernet (LAN), Wi-Fi, RS-232/485
- User interface
- Touchscreen, 800 • 480 pixel, 7" (17.78 cm)
- Data logger storage
- 4 GB Compact Flash
- Software
- PDControl, FTControl, PDAnalyze
- Thermodynamic conditions
- +10 – +40 °C, -100 – 50 mbar
- Data acquisition
- Digital, 20 MHz processor, 256 raw data channels
- Light source
- Xenon high pressure lamp 75 W
- Housing
- Table housing, optional: with mounting brackets for rack-mounting
- Support options
- Direct remote access, Palas webserver service
- Operating system
- Windows embedded
- Power supply
- 115 – 230 V, 50/60 Hz
- Power consumption
- 100 W
- Installation conditions
- +5 – +40 °C (control unit)
- Dimensions
- 185 • 450 • 315 mm (H • W • D) (19")
- Weight
- Control unit: approx. 8 kg, sensor: approx. 18 kg